ULTIMATE ANALOGUE PRODUCTIONS TEST LP - für Fozgometer zur korrekten Tonabnehmer Azimuth Justage

Artikelnummer: 68410

55,00 €
inkl. MwSt., zzgl. Versand
sofort lieferbar
Lieferzeit: 5-7 Tag(e)

Beschreibung

THE ULITMATE ANALOGUE PRODUCTIONS TEST LP

Diese Testschallplatte wird speziell für den Musical Surroundings Fozgometer empfohlen. Für eine korrekte Azimuth Einstellung und Justage Ihres Tonabnehmers.

“I used the Fozgometer as described in the instructions and using the Analogue Productions The Ultimate Analogue Test LP, I obtained readings that matched what I obtained using the digital oscilloscope…I feel it is a reliable tool to use for setting azimuth.” – Michael Fremer, Analog Planet USA

“Provides an ingenious and not too expensive solution, which is designed to be used in conjunction with The Ultimate Analogue Test Disc…the Fozgometer is very simple to use.” – Chris Martens, HiFi+ UK

A test record to provide the basic test signals necessary to calibrate a turntable or cutting lathe as simply as possible. Recommended for use with the Musical Surroundings Fozgometer.

  • Produced by Clark Williams and Barry Wolifson
  • Cut at Sterling Sound on a Neumann VMS-80 cutting lathe with a newly rebuilt SX-74 cutterhead

Track list

Side 1
General Reference Level - This 1kHz reference tone will allow you to establish a "base level" for all measurements.

Track 1. 1 kHz reference tone 7cm/s lateral in phase (mono)

Azimuth Adjustment - The object is to sit the stylus exactly perpendicular in the groove.

Track 2. 1 kHz reference level, left channel only
Track 3. 1 kHz reference level, right channel only

High Frequency Adjustment - Tracks 4,5 and 6 are used to calibrate the RIAA high frequency equalizer of a phono preamp. This will be used to calibrate a mastering lathe´s phono preamplifier or any phono preamplifier that has these adjustments.

Track 4. 1 kHz tone at -20dB below reference level, lateral

Track 5. 10 kHz reference tone at -20dB, lateral

Track 6. 1 kHz to 20 kHz sweep at -20dB, lateral

Low Frequency Adjustment - Tracks 7 and 8 are used to calibrate the RIAA low frequency equalizer of a phono preamp.

Track 7. 1 kHz to 20 Hz sweep at 0VU, lateral

Track 8. 100 Hz reference tone at 0VU, lateral

VTA adjust

Track 9. VTA adjust

Wow & Flutter

Track 10. Standard Wow & Flutter test signal; 3150 Hz

Side 2

Track 1. Anti-skating test; 315 Hz amplitude sweep to +12dB, lateral

Track 2. Pink noise lateral (used for cartridge "demagnetizing")

Track 3. Pink noise vertical (used for cartridge "demagnetizing")

Track 4. 1 kHz at reference level, vertical

Track 5. 1 kHz to 10 Hz sweep at -20dB below reference level, vertical

Track 6. Silent groove for bearing rumble and table isolation

Zusätzliche Produktinformationen

Kategorie
Justage / Einstellung (Plattenspieler, Tonabnehmer, Tonarm)
Azimut Einstellung
Ja